Chinese Night heater 2Kw

Discussion in 'Mech Tech' started by bluerustybucket, Oct 8, 2018.



  1. Rubbish photo but it looks alot smaller when in place. [​IMG]

    Sent from my Pixel 5 using Tapatalk
     
    iblaze, paradox and PanZer like this.
  2. Looks fine. Should be able to fill that without getting diesel everywhere :thumbsup:
     
    grandmst likes this.
  3. bluerustybucket

    bluerustybucket Supporter

    How many litres is it ?
     
  4. I believe around 8L

    Sent from my Pixel 5 using Tapatalk
     
    PanZer and bluerustybucket like this.
  5. I'm impressed with the workmanship but it hasn't any benefits over the plastic ones which at least let you get a visual on how much fuel is left ??



    Sent from my SM-G960F using Tapatalk
     
    iblaze and snotty like this.
  6. I run a afterburner unit so in theory I attach a fuel gauge if I wanted to one of the IO pins.

    But a quick look in the tank should do the job for now.

    Sent from my Pixel 5 using Tapatalk
     
    EggBoxes and PanZer like this.
  7. [​IMG]

    Are these things ok on the angle under the bed?
    Seems a lot less stuff underneath to avoid there!
    And there’s just about enough exhaust pipe supplied to send it out the opposite side from sliding door!
     
  8. I’m sure it ok, as long as the air and exhaust pipe are not vertically pointing upwards.


    Sent from my iPhone using Tapatalk
     
  9. No, not that way round, the glow plug has to be at the top, or it will leak fuel out of the air bleed hole.
     
    Lasty and iblaze like this.
  10. So pointing the other way would be ok?
    Trouble with that is less possibilities for the heat outlet because of the cupboard arrangement without miles of trunking, nothings ever simple [​IMG]
     
    PanZer likes this.
  11. As bigherb says.. depends which way you swing.... If its.like an eberspacher

    [​IMG]

    Sent from my SM-T580 using Tapatalk
     
    snotty likes this.
  12. So ok
    [​IMG]


    Not ok ?
    [​IMG]
     
    Kruger and Surfari like this.
  13. My one works fine , but you made me wonder [​IMG]
    [​IMG]


    Sent from my iPhone using Tapatalk
     
  14. How long you had it fitted ? Ive seen comments where the green fuel pipe hardens and splits ? Your ok ?
     
  15. I have also ! I’ve purchased the alternative pipe recommended by those on the Chinese heater group in case. I’ve only used a few times so I’m going to put it to the test and see
    At the moment I have a quick release attachment for when I’m stationary but my intention it to have a cradle for an under slung tank


    Sent from my iPhone using Tapatalk
     
  16. Have you got a link to quick release ? Ta
     
  17. Mick , I’ll check later


    Sent from my iPhone using Tapatalk
     
    Kruger and 3901mick like this.
  18. Kruger and 3901mick like this.
  19. Yes top one is OK, this hole below the glow plug must not face downwards.
    Glowplug Air Port.jpg
     
  20. Use a turret mounting plate if you are going through a ridged floor.
    Turret.jpg
     
    Lasty, Kruger, theBusmonkey and 4 others like this.