  1. Ok. My guesses are:
    1 you have a leak on the system (unlikely)
    2 from the high pressure in operation that the expansion vessel and pressure relief valve need replacement. Put a sandwich bag over the prv discharge pipe outside. If it’s got water in it then bingo there’s the problem (v common)
    3 the heat exchanger is pin holed and you are losing water down the condensate pipe which is why you never find it (rare as hens teeth)

    how confident are you in checking the expansion vessel your self?
     