    Ah, I just used tight fitting gromets. I'll try & find a picture
     
    AndyC likes this.
  2. I'm sure on the metal roof that'll be fine.
    After all, the poptop roof protect it from the elements.

    Any idea on the thickness of the roof(s)?!!
     
  3. theBusmonkey

    theBusmonkey Sponsor

    Correct. That's what I figured! The metal roof is only thin, I dunno around or slightly less than a mm maybe?

    So, the panels are wired in parallel giving 180 watts/12v. They are connected using MC4 branch connectors which take + & - from each of the panels & output one + & one - cable down to the battery terminals.
    The branch connectors are up under the roof & the holes through the roof into the passenger compartment are effectively above the LB.

    I didn't really want cables running down the vents as they could be an additional & more focussed source of water onto the terminals but TBH if the cables are kinked upwards before connecting to the terminals there won't be a problem if you do go in through the vents like @Zebedee has :thumbsup:. Just personal preference.

    Panels riveted on :eek:with large grommets...
    P1040599.jpg

    MC4 branch connectors connecting the 4 wires in to two out...(I coded the black wires with red & earth tape so Mr Stupid here couldn't get them wrong)
    P1060394.jpg

    In through the roof...this is an embarrassing picture, I've since removed the hastily installed grommets & sealed the paint work properly:oops:
    P1060395.jpg

    So, I didn't really over-think it @AndyC , & in the last 3 years we've not had a leak or issue with the instal.
    Oh & done loads & loads of off grid camping (over 100 nights not on campsite electric with the OG Westy fridge, propex & all the other gumpf we run off DC)
     
    Last edited: Feb 12, 2017
    Lardy, geordieandy, CollyP and 2 others like this.
  4. Perfect. Just the photos I needed. thanks
     
  5. Got some little rubber grommets.

    Just need the Sikaflex adhesive now.

    And some warm weather to fit it all!
     
  6. Any suggestions on cable to use from MPPT controller to the battery?

    Despite buying a kit, it didn't come with this cable!

    Or can I use some of the cable that goes from panel to MPPT?
     
  7. You just need cable that can handle the amps your MPPT puts out so if you bought a 20A one then normal automotive cable of that rating is fine.
     
    AndyC likes this.
  8. Perfect.

    So I have a 10a MPPT, so 17a is more than enough.
     
  9. theBusmonkey

    theBusmonkey Sponsor

    Yep sound advice from @Bertiebot or alternatively simply use 2 lengths of the same 4mm cable that connects the controller to the panels. That'll keep it nice & simple and you know that way you can never exceed the cable rating ;)
     
  10. Fiiiiinally getting round to fitting this!

    Wired in controller end of things at weekend.

    Just plugged in solar panel to test all ok

    Getting these readings. Seem ok for a cloudy day?

    [​IMG]

    [​IMG]
     
    Lardy and Razzyh like this.
  11. Razzyh

    Razzyh Supporter

    Have you read the manual?

    What's the light bulb + & -?
     
  12. sANDYbAY

    sANDYbAY On benefits-won't sponsor!

    It's for a power supply directly from the panels. Indicated by the little light bulb on the display in the controller.
     
    theBusmonkey, Razzyh and AndyC like this.
  13. Manual doesn't specify what a good reading should be.

    Light + - is for a direct 12v feed out of the controller.
     
  14. Wish my roof was like that or atleast flat, I had a look at the rigid frame panels but mounting on my Devon roof I think the wind would get under it and lift it up!!
    Problem is raised sections running the length of the roof.
     
  15. theBusmonkey

    theBusmonkey Sponsor

    Exactly that! The manuals often call it an output for a load using a light as an example. I've wired our load outputs to a rear mounted 12v accessory socket that makes it just a little easier to use the compressor on the rear tyres and to run the shower;)
     
  16. sANDYbAY

    sANDYbAY On benefits-won't sponsor!

    I've got raised sections running across my roof and the sikaflex does a good job of keeping the panels where I put them, (so far). I have noticed a little bit of wind drumming from them at about 85 mph but it settles down again once I go past 90.
     
    Bertiebot, Razzyh and yorkieman like this.
  17. Keeling54

    Keeling54 Supporter

  18. Andy, do us a favour, can you take a zoomed out photo of the controller. I would love to fit solar, but I'm running out of space to fit more gadgets. Just wanted to view the controller in scale.
     
  19. scrooge95

    scrooge95 Moderator and piggy bank keeper

    I think your roof must be like mine then. I haven't got around to climbing up and measuring the width of the peaks and troughs in it yet, but I did spy these on ebay and wondered if they might fit in the lower sections (or higher ones for that matter) :
    http://www.ebay.co.uk/itm/50W-flexi...484521?hash=item1a06198169:g:0HQAAOSwT5tWJ7VI
    Like I say, I haven't measured yet, but two linked together.... might just do the trick.....
    (a project for the future for me, but it's good to plan ahead ;))
     
    Lardy likes this.
  20. Will do.

    I'd say it's about the size of..... A5 bit of paper maybe?

    I have it fitted to the rear of the Westy cupboard.

    Will get a photo later.
     
    Fil6 likes this.