Building in a battery charger

Discussion in 'Mech Tech' started by Zed, Oct 13, 2015.

  1. Zed

    Zed Gradually getting grumpier

    I wonder why I worry, when I squatted in London we nicked the elc by poking a 10mm thick bundle of copper wire into the main fuse fitting with a stick. We then all had a 2 bar elec fire and the oven and all 4 hot plates were on full from when we moved in. We turned 'em down to cook if we weren't cooking on an upturned 2 bar fire. Our main fuse glowed bright green and lit the hallway at night. :D
     
    paulcalf and volkswombat like this.
  2. theBusmonkey

    theBusmonkey Sponsor

    haha Health & Safety was only invented in 1974, so I guess if your bus is older than that it don't matter what you do!
     
  3. Which. The ones in the sockets are connected as per normal then theres a common earth terminal in the enclosure which connects the supply flex from the inlet to the outgoing flex earth wire and a bonding cable to the chassis, i either used 4 or 6 mm cant recall.

    image.jpeg
     
    volkswombat and zed like this.
  4. theBusmonkey

    theBusmonkey Sponsor

    neat. it doesn't need to be complicated! I guess if it tripped, you'd just need to switch something off.
     
  5. volkswombat and zed like this.
  6. Zed

    Zed Gradually getting grumpier

    Expand please, are you saying there's a problemo with the Dickster's setup?
     
    volkswombat, theBusmonkey and Dicky like this.
  7. Zed

    Zed Gradually getting grumpier

    Dicky likes this.
  8. Zed

    Zed Gradually getting grumpier

    I've ordered MXS10 at £105 delivered. Seems MSX7 are £95 so not a great deal in it?
     
    Dicky likes this.
  9. Thats the beauty of sockets. You Can unplug everything.. A neutral earth fault fault on a hard wire zig unit on a 6amp mcb where the loads are split anf the sockets are seperate and your average punter is up merd alley as they wont find it and the Rcd wont reset. Why fill your cupboards up with electrical shizzle or risk not being protected. Where zed is talking about putting is inlet is right above where ive got me breaker. You can have the ctek in the bus rather than the engine bay feeding into the leisure circuit. Provided all your 12 volt wiring is big enough to keep the volt drop down then the ctek could go amywhere. All cables are flexes, or should be. Easy peasy as uncle dave would say....cheap as....
     
    volkswombat and theBusmonkey like this.
  10. Sounds good. I got the 7 as it was cheap off your builder matey chap who flogged his bus.... I think i would have gone for 10 as well tbh
     
  11. Don't like the metal back boxes though,deep too
     
    Dicky likes this.
  12. Zed

    Zed Gradually getting grumpier

    You mean below, but in fact I've ended up with a space between RR bed and cupboards that this would fit in. :)
    Ken Regency?
     
  13. I can wire it and send it as a kit if you want.
     
  14. its not permanent to be honest. Didnt want to attack the bed front with a hole for a plasterboard box and then change my mind. A nice flush one will be fitted at some point.
     
    Richard W12 likes this.
  15. Zed

    Zed Gradually getting grumpier

    I don't have a box big enough for a bus. :)
    I can manage I expect, when it comes to it I can post pics on here and be told why I would fry if I were to plug it in. :)
     
    MK-Bay and theBusmonkey like this.
  16. No. Makes life easier tbh.
     
  17. no you muppet. I can prewire it for you, the enclosure and rcbo. Its not difficult but would be fiddley in situ.
     
    zed, theBusmonkey and Richard W12 like this.
  18. Yes and yes. Nice chap!
     
  19. Btw. Dont ask to see my 12 volt set up as it looks like a frankenstein experiment. Indeed someone within earshot described it as steampunk. I like that!
     
    zed likes this.
  20. Zed

    Zed Gradually getting grumpier

    You wouldn't know it, but I used to design lightning protection and earthing systems for equipment mounted on steel platforms under high voltage pylons. You had to be able to get on and off the insulator mounted platforms without being killed if lightning were to strike while you had a foot on the ground and a hand on the equipment platform. This included having to prevent the lightning getting at our independent power supply. Every pylon has different characteristics depending on the ground conditions.

    A bit like History at school, I'm grateful to have forgotten the details of all this now and thankful that you guys are still switched on. :) :cheers:
     